|
|
Fluke 3300 Clamp-on Current Transformer
|
|
Current range: 10-3000A
Accuracy: 2% RDG +/- 0.05% FS
Frequency response: 5 kHz
Jaw opening: 3.5 x 4.5” dia. (9 x 11 cm)
|
Current Clamp DMM Accys
|
|
|
|
Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe, 2 Feet Long For the Fluke 1750 Power Recorder
|
|
The Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe is an ac current probe utilizing the Rogowski principle. The Fluke 3310PRTF Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors. |
Current Clamp DMM Accys
|
|
|
|
Fluke 3212-PR-TF 5000A Flex Thin Flex Current Probe, 4 Feet Long For the Fluke 1750 Power Recorder
|
|
The Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe is an ac current probe utilizing the Rogowski principle. The Fluke 3310PRTF Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors. |
Current Clamp DMM Accys
|
|
|
|
Fluke 3583R Split-Core Current Transformers
|
|
Current range: 0.01 – 10A
Accuracy: 1% RDG +/- 0.5% FS
Frequency response: 5 kHz
Length: 7/16” (1 cm)
|
Current Clamp DMM Accys
|
|
|
|
Fluke 3584R Split-Core Current Transformers
|
|
Current range: 0.1 – 40A
Accuracy: 1% RDG +/- 0.5% FS
Frequency response: 5 kHz
Length: 7/16” (1 cm)
|
Current Clamp DMM Accys
|
|
|
|
Fluke 3585R Split-Core Current Transformers
|
|
Current range: 0.5 – 1-0A
Accuracy: 1% RDG +/- 0.5% FS
Frequency response: 5 kHz
Length: 7/16” (1 cm)
|
Current Clamp DMM Accys
|
|
|
|
Fluke TPS CLAMP 10 A / 1 A Clip-on Current Transformer
|
|
Measuring Range selectable per software:0.01A to 1A0.1A to 10A
Peak current for sinusoidal currents:3.7A to 37A
Intrinsic error: 0.5%
Frequency Range: 40Hz to 10kHz
Operating Voltage: 300V CAT IV
Phase Error: 0.5°
Jaw Opening: <15mm diameter or 15x17mm bus bars
Errors in % of measuring range at 23°C ± 2K; 74°F±2K, for 48 to 65Hz
Phase angle error at nominal current
Imax maximum current without time limit (for ac and dc shunts)
|
Current Clamp DMM Accys
|
|
|
|
Fluke TPS CLAMP 200 A / 20 A Clip-on Current Transformer
|
|
Measuring Range selectable per software:0.2 A to 20 A 2 A to 200 A
Peak current for sinusoidal currents74 A 300 A
Intrinsic error 0.5%
Frequency Range 40 Hz to 10 kHz
Operating Voltage 300 V CAT IV
Phase Error 0.5 °
Jaw Opening < 15 mm diameter or 15 x 17 mm bus bars
Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz
Phase angle error at nominal current
Imax maximum current without time limit (for ac and dc shunts)
|
Current Clamp DMM Accys
|
|
|
|
Fluke TPS CLAMP 50 A / 5 A Clip-on Current Transformer
|
|
Measuring Range selectable per software 1 A to 100 A 5 A to 500 A
Peak current for sinusoidal currents 240 A 1350 A
Intrinsic error 1%
Frequency Range 45 Hz to 3.0 kHz
Operating Voltage 300 V CAT IV
Phase Error 0.5 °
Jaw Opening 45 cm length
2 m cable
Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz
Phase angle error at nominal current
Imax maximum current without time limit (for ac and dc shunts)
|
Current Clamp DMM Accys
|
|
|
|
Fluke TPS FLEX 18-TF 100A/500A Thin Flex Flexible Current Probe with 18-inch Cable For the Fluke 1760 Power Recorder
|
|
Measuring Range selectable per software:
1A to 100A
5A to 500A
Peak current for sinusoidal currents:
240A
1350A
Intrinsic error 1%
Frequency Range 45 Hz to 3.0 kHz
Operating Voltage 300 V CAT IV
Phase Error 0.5°
Jaw Opening 45 cm length 2 m cable
|
Current Clamp DMM Accys
|
|
|
|
Fluke TPS FLEX 24-TF 200A/1000A Thin Flex Flexible Current Probe with 24-inch Cable For the Fluke 1760 Power Recorder
|
|
Measuring Range selectable per software:
2A to 200A
10A to 1000A
Peak current for sinusoidal currents:
480A
2700A
Intrinsic error 1%
Frequency Range 45 Hz to 3.0 kHz
Operating Voltage 600 V CAT IV
Phase Error 0.5°
Jaw Opening 45 cm length 2 m cable
|
Current Clamp DMM Accys
|
|
|
|
Fluke TPS FLEX 36-TF 3000A/6000A Thin Flex Flexible Current Probe with 36-inch Cable For the Fluke 1760 Power Recorder
|
|
Measuring Range selectable per software:
30A to 3000A
60A to 6000A
Peak current for sinusoidal currents:
10kA
19kA
Intrinsic error 1%
Frequency Range 45 Hz to 3.0 kHz
Operating Voltage 300 V CAT IV
Phase Error 0.5°
Jaw Opening 45 cm length 2 m cable
|
Current Clamp DMM Accys
|
|
|
|
Fluke 373 True-RMS 600A/600V AC Clamp Meters
|
|
600 A ac current measurement with fixed jaw
600 V ac and dc voltage measurement
True-rms ac voltage and current for accurate measurements on non-linear signals
Resistance measurement to 6000Ω with continuity detection
1000 µF capacitance measurement
State of the art signal processing allows for use in noisy electrical environments while providing stable readings
Large, easy to read, backlight display automatically sets the correct measurement range so you do not need to change switch... |
Current Clamp Meters
|
|
|
|
Fluke 365 True-rms AC Clamp Meter with Detachable 18mm Jaw
|
|
200A ac and dc current measurement with detach-able jaw
600V ac and dc voltage measurement
True-rms ac voltage and current for accurate measurements on non-linear signals
6000Ω resistance measurement with continuity detection
Detachable jaw makes accessing wires and viewing the display easier
Built in flashlight/torch allows for easy illumination and identification of wires
CAT III 600V safety rating
Compact design fits in your hand and can be used while wearing personal protective... |
Current Clamp Meters
|
|
|
|
Fluke 323 400A AC, 600V AC/DC True-RMS Clamp Meter
|
|
400 A AC current measurement
600 V AC & DC voltage measurement
True-rms ac voltage and current for accurate measurements on non-linear signals
Resistance measurement up to 40 kΩ with continuity detection
Features:
Slim, ergonomic design
CAT IV 300V/CAT III 600 V safety rating
Hold button
Two-year warranty
Soft carrying case
|
Current Clamp Meters
|
|
|
|
Fluke 324 40/400A AC, 600V AC/DC True-RMS Clamp Meter with Temperature, & Capacitance Measurements
|
|
400 A AC current measurement
600 V AC & DC voltage measurement
True-rms ac voltage and current for accurate measurements on non-linear signals
Resistance measurement up to 40 kΩ with continuity detection
Temperature and capacitance measurement
Features:
Slim, ergonomic design
Backlight display
CAT IV 300V/CAT III 600 V safety rating
Hold button
Two-year warranty
Soft carrying case
|
Current Clamp Meters
|
|
|
|
Fluke 325 40/400A AC/DC, 600V AC/DC True-RMS Clamp Meter with Frequency, Temperature, & Capacitance Measurements
|
|
400 A ac and dc current measurement
600 V ac and dc voltage measurement
True-rms ac voltage and current for accurate measurements on non-linear signals
Resistance measurement up to 40 kΩ with continuity detection
Temperature and capacitance measurement
Frequency measurement
Min/Max functionality
Features:
Slim, ergonomic design
Backlight display
CAT IV 300V/CAT III 600 V safety rating
Hold button
Two-year warranty
Soft carrying case
|
Current Clamp Meters
|
|
|
|
Fluke 353 AC/DC TRMS 2000 A Clamp Meter; Amps Only For Voltage Measurements, See : Fluke 355 Clamp Meters
|
|
Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc
The large 58 mm (2.3 in) jaw capacity is suitable for large, or multiple conductors
CAT IV 600 V, CAT III 1000 V rating for added user protection
In-rush current measurement captures 'power-on' surge current with accuracy and repeatability
Accurately measure frequency up to 1 kHz for optimum troubleshooting
Quickly analyze readings using the MIN, MAX, and AVG functions
A... |
Current Clamp Meters
|
|
|
|
Fluke 355 AC/DC TRMS 2000 A Clamp Meter See Also: Fluke 353 Clamp meter
|
|
Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc
The large 58 mm (2.3 in) jaw capacity is suitable for large, or multiple conductors
CAT IV 600 V, CAT III 1000 V rating for added user protection
In-rush current measurement captures 'power-on' surge current with accuracy and repeatability
Accurately measure frequency up to 1 kHz for optimum troubleshooting
Quickly analyze readings using the MIN, MAX, and AVG functions
A... |
Current Clamp Meters
|
|
|
|
Fluke 374 600A/600V True-RMS AC/DC Clamp Meter
|
|
600A AC and DC current measurement with fixed jaw
2500 A ac current measurement with iFlex flexible current probe (sold separately)
600 V ac and dc voltage measurement
True-rms ac voltage and current for accurate measurements on non-linear signals
Resistance measurement of 6000 Ω with continuity detection
Min, max, average and inrush recording to capture variations automatically
500 mV dc measurement range to interface with other
CAT IV 600V, CAT III 1000 V safety rating
iFlex... |
Current Clamp Meters
|
|